Product description
3 Product description
3.1 General description
AHU Kits connect Panasonic ECOi, ECO G and PACi outdoor units to third-party air handling
unit systems, using the same refrigerant circuit as the VRF system.
Application examples for Panasonic AHU Kits are hotels, ofces, server rooms or all large build-
ings where air quality control such as humidity and temperature control and fresh air is needed.
The Panasonic AHU Kits offer a wealth of connectivity possibilities so that they can be easily
integrated into many systems.
The new AHU Kit has been developed to better meet customer demand:
Two versions available depending on the required functionality (light or ad-
vanced version)
IP65 enclosure providing the possibility for outdoor installation
0–10 V demand control (included on the CZ-CAPBC2 interface)*
Easy control by BMS
* Only available with ECOi and PACi Elite units from 6 kW up to 14 kW (for PACi Elite units from 20/25 kW available
on request)
Featuresandbenets
The system is controlled by the air intake (or room return air) temperature in the
same way as a standard indoor unit. Selectable modes: Automatic / Cooling /
Heating / Fan / Dry (equivalent to Cooling).
Easy integration into BMS or AHU control systems using demand control: 40 to
115 % (5 % steps) of nominal current by 0–10 V input signal (advanced version
only)
Room supply air temperature can be controlled by the additional thermostat, its
supply air temperature sensor and the 0–10 V input signal for enhanced comfort
and efciency (advanced version only).
Target temperature setting based on ambient temperature with CZ-CAPBC2
using 0–10 V signal (advanced version only).
Connectable with P-LINK system.
Fan control signal from the PCB can be used for controlling the air volume of an
external fan (High/Mid/Low and LL for Th-OFF). (Need to change the fan control
circuit wiring at eld.)
Defrost operation signal, Thermo-ON/OFF states output
Drain pump control (Drain-pump and the oat switch to be supplied in local)
Basic humidier control output (humidier eld supplied)
Alarm and operation output
3.2 Scope of supply
The AHU Kits are supplied in two versions, “light” or “advanced”, and can be selected based on
the required functionality.