If the call is not answered before the recall or reversion timers have elapsed then the call will recall to the
transferring extension.
Group numbers cannot be assigned for use in hunt groups and manager secretary groups.
If the group number is matched to an extension, the extension cannot be the destination of a Call Forward. If the
matched extension sets a Call Forward the group ringing function will be disabled.
Off hook signalling does not operate for group ringing calls.
If the group number is assigned to an FF key or DSS key, at another extension, it will not light when the group is
called and the call cannot be picked up using the key.
Group Ringing - CPC-EX v2.1
Membership of the DDI / Ring Groups has been extended from the original 8 to 32 members with the introduction
of the CPC-EX v2.1 software.
A new Hunt Group type has also been added to the software for the exclusive use of DDI calls. There are an
additional 16 DDI Hunt Groups allowing 16 members of each. Members can be extensions or DDI Ring Groups,
and the hunting mode is circular, with no answer or busy searching. No follow on group or alternative hunting
modes are supported. The existing Hunt Group operation is unchanged
For DDI Ring Groups to be included in a Hunt Group they will require a virtual extension number to be assigned to
reference them by. Extensions cannot be members of more than 1 DDI Hunt Group and cannot be included in a
more than 1 Ring Group assigned to a DDI Hunt Group, but can be individually in the same DDI Hunt Group as a
Ring Group in which it is also a member.
Group membership conditions for normal Hunt Groups are unchanged. (see following example )
In this example:
a) Cannot assign EXTN 300 to B, D and E
b) Cannot assign GROUP 310 to A, B, D and E
c) Cannot assign GROUP 320 to A, B, C and E
d) Cannot assign GROUP 330 to A, B, C and D
The original Hunt Group hunting takes precedence over the DDI Hunt Groups. If there are calls to A and C and
300 becomes idle, the call on A will have priority over the call to C.