Panasonic Digital Business System - Operating Instructions
March 1997 Issue 24
124
Call Traffic Monitoring
The operator has a range of functions which are used to examine accumulated system statistics regarding call
usage by lines and extensions.
When using DISA break out and call charging information is available (Meter Pulse Detection or ISDN Call Charge
Information) the operator extension can be used to check the accumulated totals for each ID code.
[Operation]
1 Press ON / OFF
2 Press CONF
3 Dial #
4 Enter the code required - see table below
5 Press ON / OFF
The code options are
Code Meaning
90NN Displays the number of outgoing calls on line NN
NN = Line number (01 - 48)
91NN Displays the number of incoming calls on line NN
NN = Line number (01 - 48)
92SSD Displays the number of times the specified SSD has been used
SSD = SSD number (00 - 89)
93 Clears count data in items 90 ,91 and 92 to 0
94NN Displays the cumulative call charges for line NN
NN = Line Number (01 - 48) . Meter pulse detection required.
95NNNN Displays the cumulative call charges for extension NNNN
NNNN = Extension number . Meter pulse detection required.
96 Clear charge data for all lines and extensions 94 and 95 above to 0
97 Print all charge data on the call logger.
Call logger required.
00 (1-5) (1-5) is the number of the DISA break out ID code to be checked.
Ending with * will clear data to 0, or # will send the displayed data to
the call logging output.