9
Before connecting the Data Multiplex Unit, check how the
DIP switches are set on the rear panel in cases where the
system setup must be changed.
■ Setting Communication Mode
● Panasonic Security Data Mode
Check that Dip Switches SW3 and SW4 are up.
● Camera Communication Mode
Check that Dip Switch SW3 is down and Dip Switch
SW4 up.
■ Setting VS or VD Signal Output
● Supplying Video Drive Signal in Internal Sync
Mode*
Check that Dip Switch SW1 is down (VD).
DIP SWITCH SETTING
* Synchronized vertical drive signal is supplied in case
of signal input to VS/VD IN connector.
● Supplying Synchronized Signal Input to VS/VD
IN Connector
Check that Dip Switch SW1 is up (THROUGH).
■ Setting the Communication
Mode via RS485 or Data Port
● Termination
Check that Dip Switch SW5 is down (ON).
Note: In case of using two Data Multiplex Units or
more, set Dip Switch SW5 on only one point at the
end position of the unit to the down position.
● Data Line Selection Mode
Set DIP Switch SW6 to the 4-LINE or 2-LINE position
according to the desired data line selection mode.
4-LINE: Full Duplex
2-LINE: Half Duplex
The initial factory setting is 4-LINE.
Note: Set SW6 to 4-LINE for communication in
Panasonic Security Data mode.