17
(4) Parity Check Setting
1. Display the COMMUNICATION menu.
2. Move the cursor to PARITY CHECK by pressing button
1 (C) or button 2 (D), then select the desired type of
parity check (NONE, EVEN or ODD) by pressing button
3 (–) or button 4 (+).
The initial factory setting is NONE.
(5) Stop Bit Setting
1. Display the COMMUNICATION menu.
2. Move the cursor to STOP BIT by pressing button 1 (C)
or button 2 (D), then select the desired number of stop
bits, 1 or 2 by pressing button 3 (–) or button 4 (+).
The initial factory setting is 1 bit.
(6) Wait Time Setting
1. Display the COMMUNICATION menu.
2. Move the cursor to WAIT TIME by pressing button 1
(C) or button 2 (D), then select the desired wait time
(OFF, 100, 200, 400, or 1000 ms) by pressing button 3
(–) or button 4 (+).
The initial factory setting is OFF (No retry).
(7) Delay Time Setting
1. Display the COMMUNICATION menu.
2. Move the cursor to DELAY TIME by pressing button 1
(C) or button 2 (D), then select the desired delay time
(OFF, 10, 20, 40, or 100 ms) by pressing button 3 (–) or
button 4 (+).
The initial factory setting is OFF.
(8) XON/XOFF Setting
1. Display the COMMUNICATION menu.
2. Move the cursor to XON/XOFF by pressing button 1
(C) or button 2 (D), then select the desired mode,
NOT USE or USE, by pressing button 3 (–) or button 4
(+).
The initial factory setting is NOT USE.
(1) Camera Addresses Setting
1. Display the COMMUNICATION menu.
2. Move the cursor to CAM ADDRESS by pressing button
1 (C) or button 2 (D), press the SUSPEND/SET button,
and then select the desired camera addresses in the
range of 1 to 99 or No Camera by pressing button 3 (–)
or button 4 (+).
Note:
• Check before the above setting that the UNIT
switch is at 0. For address setting, see page 10.
• Before switching the Data Multiplex Unit back on,
remember that address setting with the UNIT switch
has priority to the above setting.
(2) Baud Rate Setting
1. Display the COMMUNICATION menu.
2. Move the cursor to BAUD RATE by pressing button 1
(C) or button 2 (D), then select the desired baud rate
(19200, 9600, 4800, or 2400 bps) by pressing button 3
(–) or button 4 (+).
The initial factory setting is 19200bps.
(3) Data Bit Setting
1. Display the COMMUNICATION menu.
2. Move the cursor to DATA BIT by pressing button 1 (C)
or button 2 (D), then select the desired number of data
bits, 7 or 8, by pressing button 3 (–) or button 4 (+).
The initial factory setting is 8 bit.