7
Rear View
o Camera Input Connectors 1-4 (CAMERA IN 1, 2, 3, 4)
These connectors accept the composite video signal
from the camera.
!0 Camera Output Connectors 1-4 (CAMERA OUT 1, 2,
3, 4)
The video signal connected to the Camera Input
Connector (CAMERA IN 1, 2, 3, 4) is looped through to
these connectors.
!1 Video Input Connector (SPOT IN)
Used when multiple Data Multiplex Units are connect-
ed.
Note: To connect multiplex Data Multiplex Units, set
DAISY MODE in the System menu to ON.
!2 Video Output Connector (SPOT OUT)
This connector supplies the video output signal for the
spot monitor. It is also used when connecting multiple
Data Multiplex Units.
!3 VS/VD Input Connector (VS/VD IN)
Accepts the video sync signal (VS), or a vertical drive
signal (VD) supplied by external devices to synchro-
nize the Data Multiplex Unit with other devices.
Notes:
Connect a device supplying an external sync sig-
nal that complies with the CCIR specifications. Do
not input signals having a high jitter content such
as VTR playback signals.
To input a vertical drive signal, set VS/VD INPUT in
the System menu to VD.
!4 VS/VD Output Connector (VS/VD OUT)
This connector is used to supply the sync signal input
to the VS/VD IN connector, or the internally generated
sync signal VD, to other devices.
Note:
Set MODE Switch (1) to OFF (THROUGH) in sup-
plying the signals input to the VS/VD IN connector
to other devices.
Set MODE Switch (1) to ON (VD) in supplying the
internally generated reference sync signal VD to
other devices.
!5 Alarm/Remote Connector (ALARM/REMOTE)
The factory default setting is ALARM input. For remote
input, set TERMINAL in the System menu to REMOTE.
Can also be used as ALARM/REMOTE output terminal
by moving an internal connector. Refer to page 24 for
details.
!6 RS485 Terminal (RS485)
This terminal is used to exchange control data with the
camera site via Camera Communication mode.
!7 Data Port (DATA)
This port is used to exchange control data with the WV-
CU360 System Controller in Panasonic Security Data
mode.
Note: Cannot use both RS485 Terminal and Data port
at the same time. It can be distributed correspond-
ing to the communication mode as follows:
Camera Communication Mode: Use only the RS485
terminal.
Panasonic Security Data mode: Use only the Data
port.
!8 Dip Switches (MODE)
These switches are used to select the mode.
!9 Signal Ground Terminal (SIGNAL GND)
@0 Power Cord
RT
IN IN
CAMERA RS485
ABABG
VS/VDSPOT DATA
ALARM / REMOTE
MODE
SIGNAL GND
4321
OUT OUT
IN
OUT
4321
o
!0
!2 !4
!6
!7 !8
!1 !3 !5 !9 @0