Note: Select one of the monitors, on which the
Group Sequence is running by activating the
Alarm Mode-3, then follow the steps above to
cancel the alarmed monitors at once.
13-4. To cancel Alarm (All Monitors)
The following procedure lets you cancel all alarms at
once without selecting the monitors.
1. Press the ALT button. The LED indicator on the but-
ton lights up.
2. Press the ALL RESET button to reset all alarms at
once.
13-3.To Cancel Alarm (Plural Monitors)
Follow the procedures to cancel all alarms at once when
activating Alarm Mode 1 or 2.
1. Select the alarmed monitor. Refer to Monitor
Selection on page 50.
Select monitor 1 on activating Alarm Mode-1 or
select one of monitors 1 - 4 on activating Alarm
Mode-2.
2. Press the ALL RESET button to reset all alarms at
once.
13-5. To Suspend Alarm
The following function is used to suspend activation of
the alarm without amending the current alarm mode
setup.
RECALL
NO DATA ALARM
08 12.FEB 18:31:10 3-32 MODE3
07 12.FEB 18:30:01 3-12 MODE3
. . . . .
. . . . .
. . . . .
02 1.JAN 18:30:10 2-10 MODE2
01 1.JAN 8:05:51 0-32 MODE1
3. Press the HISTORY FWD button to select the next
page. Press the HISTORY BACK button to select
the previous page.
2. Press the ACK/RESET button once for alarm
acknowledgement.
The LED indicator on the button blinks rapidly.
3. Press the ACK/RESET button once again for alarm
reset.
The LED indicator light goes off.
3. To cancel this function, press the ALT button, then
press the ACK/RESET button.
The LED indicator light turns off.
Note: If the alarm is received during this mode, the
alarm is not activated on the monitor. However
the received alarms are memorized on the
Alarm Logs.
14. Alarm Recall
The following function is used to display the Alarm Logs
(Activated alarm history).
There are ninety-nine (99) alarm records stored in
chronological order in thirteen (13) pages of tables.
The tables also show all involved monitor numbers when
Alarm Mode-3 is activated, and indicates the alarm
mode number when Alarm Mode-1 or Alarm Mode-2 is
activated.
1. Select the desired monitor to display the alarm logs.
Refer to the Monitor Selection on page 50.
2. Press the RECALL button to toggle the display of
alarm records on the selected monitor.
1. Press the ALT button. The LED indicator on the but-
ton lights up.
2. Press the ACK/RESET button to suspend activation
of the alarm.
The LED indicator on the button lights up.