Panasonic WJSX350 Instrucciones de operaciones Pagina 38

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
-36-
A L A R M M O D E 3 ( A L = 0 1 )
M O D E = – – - – –
< < M 1 M 2 M 3 M 4 > >
S S T T
< < M 5 M 6 M 7 M 8 > >
G G G G
A L A R M M O D E 3 ( A L = 0 1 )
M O D E = S P O T C A M = 0 1
P R E = 0 1
M O N I = 2 D W E L L = 1 0 S
< < M 1 M 2 M 3 M 4 > >
S S T T
< < M 5 M 6 M 7 M 8 > >
G G G G
Then press the CAM (SET) button to display the
mode setup table of the selected alarm input as
shown below.
• Mode selection on ALARM MODE3 table
Move the cursor to the MODE parameter by moving the
Joystick Controller. Then set the Mode to SPOT, TOUR
or GROUP by pressing the +1CAM INC or –1CAM DEC
button.
• Spot Mode
1. If the SPOT is selected on the above menu, the dis-
play will change as follows:
2. Move the cursor to the MONI parameter by moving
the Joystick Controller, then enter a Monitor Number
to display the spot picture by pressing the Numeric
button or the +1CAM INC or –1CAM DEC button.
Notes:
• Monitor Numbers without the S cannot be pro-
grammed on this table.
• If a correct Monitor Number is entered, the
selected monitor in the Monitor Number area is
displayed inversely.
• If an incorrect Monitor Number is entered, the
selected monitor in the Monitor Number area
blinks.
3. Move the cursor to the CAM parameter by moving
the Joystick Controller, then enter a Camera
Number by pressing the Numeric buttons or the
+1CAM INC or –1CAM DEC button.
4. Move the cursor to the PRE parameter by moving
the Joystick Controller, then enter a Preset Position
Number, if applicable, by pressing the Numeric but-
tons or the +1CAM INC or –1CAM DEC button.
5. Move the cursor to the DWELL parameter by mov-
ing the Joystick Controller, then enter the desired
Dwell Time(1-30) by pressing the Numeric buttons
or the +1CAM INC or –1CAM DEC button.
6. Press the MON (ESC) button to return to the previ-
ous ALARM MODE 3 menu.
• Tour Sequence Mode
1. If TOUR is selected on the above menu, the display
will change as follows:
A L A R M M O D E 3 ( A L = 0 1 )
M O D E = T O U R
S E Q N O. = 0 1
M O N I = 3
< < M 1 M 2 M 3 M 4 > >
S S T T
< < M 5 M 6 M 7 M 8 > >
G G G G
2. Move the cursor to the MONI parameter by moving
the Joystick Controller, then enter a Monitor Number
(1-8) to run the sequence by pressing the Numeric
button or the +1CAM INC or –1CAM DEC button.
Notes: Select a Monitor Number with T (Tour
Sequence Mode) that is previously assigned to
the Monitor Number area.
Monitor Numbers without the T cannot be pro-
grammed on this table.
3. Move the cursor to the SEQ NO. parameter by mov-
ing the Joystick Controller, then enter a Tour
Sequence Number to be run on the selected moni-
tor by pressing the Numeric button or the +1CAM
INC or –1CAM DEC button.
4. Press the MON (ESC) button to return to the previ-
ous ALARM MODE 3 menu.