Edging Wedge
Setting:
EW radius, start angle, sweep angle(,chord angle;)
Parameter : radius start angle
Format : current units clamped real
Range : -2
30
to 2
30
-1 -32768 to 32767 (modulo 360)
Default : no default no default
Parameter : sweep angle chord angle
Format : clamped real clamped real
Range : ±360° 0.5° to 180°
Default : no default
This command outlines the specified wedge.
Radius
Specifies the distance between the current pen location and the starting point of
the wedge's arc.
A wedge is a portion of a circle, and the parameter indicates a radius of a circle.
The printer interprets coordinates in user units when scaling is on and in plotter
units when scaling is off.
The sign (+) or (–) of the radius parameter determines a start position of the
start angle (zero degree).