Set Status Readback Location Unit Command
Setting:
ESC “*s#U”
Location Type Location Unit (#)
0 *:invalid location
1 *:current selection
2 *:all locations
3 0:all internal
4 0:all downloaded
1:temporarily downloaded
2:permanently downloaded
Table 3.30 *=any entered value is ignored.
This command sets the status location unit. The location unit is used in
association with the location type. The range is from 0 to 2. The default is 0.
Inquire Status Readback Entity Command
Setting:
ESC “*s#I”
#=0: font
1: macro
2: user-defined pattern
3: symbol set (Unbound scalable font)
4: font extended
This command specifies the entity type, and makes the status response to the
specified entity in the status readboack location (type and entity). The default is
not applicable.