CS/CU-UW9GKE
CS/CU-UW12GKE
AirConditioners
WARNING
Thisserviceinformationisdesignedforexperiencedrepairtechniciansonlyandisnotdesignedforusebythegeneralpublic.
Itdoesnotcontainwarningsorcautionstoadvisenon-techicalindividualsofpotentialdangersinattemptingtoserviceaproduct.
Productspoweredbyelectricityshouldbeservicedorrepairedonlybyexperiencedprofessionaltechnicians.Anyattempttoservice
orrepairtheproductorproductsdealtwithinthisserviceinformationbyanyoneelsecouldresultinseriousinjuryordeath.
1Features2
2Functions3
3ProductSpecifications6
4Dimensions10
5RefrigerationCycleDiagram14
6BlockDiagram15
7WiringDiagram17
8OperationDetails19
9
Installation
29
39
50
11DisassemblyofTheParts
12TroubleshootingGuide
13TechnicalData
14ExplodedView
15ReplacementPartsList
16ExplodedView
17ReplacementPartsList
CONTENTS
PagePage
53
55
58
59
60
61
62
63
64
65
------------------------------------------------------
--------------------------------------------------------
------------------------------------------
-----------------------------------------------------
-----------------------------------
--------------------------------------------------
-------------------------------------------------
-----------------------------------------------
---------------------------------------------------
102-way,3-wayValve
-----------------------------------------------------
--------------------------------------
----------------------------------------
--------------------------------------------------
--------------------------------------------------
-----------------------------------------
--------------------------------------------------
-----------------------------------------
OrderNo.PHAAG0707018C2
PanasonicHomeAppliancesAirConditioner
(Guangzhou)Co.,Ltd.(PHA-AG)Allrightsreserved.
Unauthorizedcopyinganddistributionisviolationof
law.
C
RR
PRECAUTIONOFLOWTEMPERATURE
Inordertoavoidfrostbite,beassuredofnorefrigerantleakageduringtheinstallationorrepairingofrefrigerationcircuit.
18ExplodedView
--------------------------------------------------
-----------------------------------------
19ReplacementPartsList
20ExplodedView
--------------------------------------------------
-----------------------------------------
21ReplacementPartsList
Vista de pagina 0
1 2 3 4 5 6 ... 64 65

Indice de contenidos

Pagina 1 - CS/CU-UW12GKE

CS/CU-UW9GKECS/CU-UW12GKEAirConditionersWARNINGThisserviceinformationisdesignedforexperiencedrepairtechniciansonlyandisnotdesignedforusebythegeneralpu

Pagina 2 - 1Features

104DimensionsIndoorUnitCS-UW9GKE496116579410(43)77049615205(20)(26.5)(16)(26.5)(27.5)(20)(382.2)(118.2)(95.8)4520.5 83.20.5LeftPipingHoleAiroutletAiri

Pagina 3 - 2Functions

IndoorUnitB A(631)(382) (118)(131)61165(420)(50)FrontViewInstallationPlateHookGasSideLiquidSideDrainPort799AirintakeSideview183AiroutletLeftPipingHole

Pagina 4

OutdoorUnitCU-UW9GKE65061.610cm100cmRequiredspaceforinstallationUnit:mm61.6888865066825023055.8293AirintakeAiroutlet10cm12TopviewFrontViewSideviewCS-U

Pagina 5

Morethan10cmMorethan100cm7804857032035216Morethan10cm105CU-UW12GKE274TopviewFrontViewSideviewUnit:mmOutdoorUnit13CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW1

Pagina 6 - 3ProductSpecifications

5RefrigerationCycleDiagramINTAKEAIRSENSORPIPINGSENSOR4-wayvalvePIPINGSENSORCoolingHeating14CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE

Pagina 7 - Rows/Stage

CS-UW9GKE/CU-UW9GKE6BlockDiagramSSR2 0115CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE

Pagina 8

CS-UW12GKE16SSR201CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE

Pagina 9

CS/CU-UW9GKE7WiringDiagramR:REDBL:BLACKB:BLUEBR:BROWNO:ORANGEGRY:GREYG:GREENY:YELLOWW:WHITEY/G:YELLOW/GREENCOMPRESSORTERMINALYELLOWREDSBLUERCTRADEMARK

Pagina 10 - 4Dimensions

CS/CU-UW12GKE18COMPRESSORTERMINALR:REDBL:BLACKB:BLUEBR:BROWNO:ORANGEGRY:GREYG:GREENY:YELLOWW:WHITEY/G:YELLOW/GREENYELLOWREDSBLUERCTRADEMARKINDOORFANMO

Pagina 11 - IndoorUnit

198OperationDetails8.1.CoolingModeOperationWhenselectingtheCoolingModeOperation,theunitwilloperateaccordingtothesettingbytheRemoteControllerorthecontr

Pagina 12 - OutdoorUnit

21FeaturesCS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKEHighEfficiencyComfortEnvironmentAirfilterwithfunctiontoreducedustandsmokeAutoRestartControlAutomati

Pagina 13

20IntakeairtemperatureEvaporatertemperature102StartStop1.5BasicTimeComp.IndoorFanOutdoorFanOperationIndicator1 137OperationstatusTimedelaysafetycontro

Pagina 14 - 5RefrigerationCycleDiagram

21AutomaticFanSpeedDuringSoftDryOperation,useremotecontrollertoselectAutoFanSpeedmode.IndoorFanSpeedisat Lo-70T240T1SloLo-OFFONOFF10670T240T110SloSloL

Pagina 15 - 6BlockDiagram

8.3.HeatingModeOperationWhenselectingtheHeatingModeOperation,theunitwilloperateaccordingtothesettingbytheRemoteControllerandtheoperationisasthefollowi

Pagina 16 - CS-UW12GKE

abcdefghijklmnopqr242343230OFFON1'2'58''30SLOSLO LO-SSLOSSLOSSLOSSLO30'150'IndoorheatexchangetTemp.IntakeTemp.BasicTimeC

Pagina 17 - 7WiringDiagram

24DeiceControlDeiceoperationistoprotecttheoutdoorunitfromfreezing.NormalDeiceOperationDeicingstarts30minutesafterheatingmodeoperationor60minutesaftert

Pagina 18

TimeGraphforOverloadDeicingabcdefghijklmnopq49Max1260'<Operationstatus>Overloadcontrola-ii-lOverloaddeicing(timer)l-m:Warmbootingcontrolm-r

Pagina 19 - 8OperationDetails

8.4.AutomaticModeOperationStandardforDeterminingOperationModeCoolingmodeSoftDrymodeHeatingmodeCoolingmodeSoftDrymodeHeatingmodeIntakeAirtemperatureSet

Pagina 20 - 8.2.SoftDryModeOperation

AUTOAUTO8.5AboutCursorKeyWhichPointsTo OFF OnRemoteControlAUTOPRESS"OFF/ON"BUTTONFANSPEEDAUTO1.2.WhentheON/OFFbuttonontheremotecontrolispres

Pagina 21 - Operationstatus

288.8AirflowDirectionControlCoolingSoftdryOperatingModeDeterminingoperationmodeManualAutoManuaAuto123451217263236ooooo12~36oo9o921294455oooooHeating9~

Pagina 23 - Manualfanspeed

OperationSTART/STOPOperationModeSelectionAutomaticOperationHeatingModeOperationCoolingModeOperationSoftDryModeOperationModeIndoorFanSpeedSelectionLowS

Pagina 25

U U U UUU

Pagina 26 - 8.4.AutomaticModeOperation

9.2.1. SELECTTHEBESTLOCATION(Referto"Selectthebestlocation"section)9.2.2. HOWTOFIXINSTALLATIONPLATEThemountingwallisstrongandsolidenoughtopr

Pagina 27 - 8.7Autorestartcontrol

-33 -PipingConnectingcableMorethanapprox.95cmSleeveforpipingholeDrainhoseMakesuredonotfastenandcollectthepowersupplycordintothepipingtrough,otherwise,

Pagina 29

HOWTOTAKEOUTFRONTGRILLEPleasefollowthestepsbelowtotakeoutfrontgrilleifnecessarysuchaswhenservicing.1.Settheverticalairflowdirectionlouvertothehorizont

Pagina 30

U U U U

Pagina 31

U G U GU U U U

Pagina 33

10InstallationandServingAirConditionerUsingR410A10.1.OUTLINE10.1.1AboutR410ARefrigerant1.ConvertingairconditionerstoR410ASinceitwasdeclaredin1974thatc

Pagina 34

IndoorUnitWhentheremotecontrolcannotbeusedorforrepairingandtesting,pleaseusethisbutton.PowerSwitchON/OFFOperationIndicationLampsPower(green)Timer(oran

Pagina 35 - 9.3.OUTDOORUNIT

d.R410ArefrigeratingmachineoilConventionally,mineraloilorasyntheticoilsuchasalkylbenzenehasbeenusedforR22refrigeratingmachineoil.Becauseofthepoorcompa

Pagina 36

10.2.2.R410ATools1.Coopertubegaugeforclearanceadjustment(usedwhenflaringwiththeconventionalflaringtool(clutchtype))Thisgaugemakesiteasytosettheclearan

Pagina 37

5.CharginghoseThepressureresistanceofthecharginghosehasbeenraisedtomatchthehigherpressureofR410A.ThehosematerialhasalsobeenchangedtosuitHFCuse,andthes

Pagina 38

8.ElectronicscaleforrefrigerantchargingBecauseofthehighpressureandfastvaporizingspeedofR410A,therefrigerantcannotbeheldinaliquidphaseinsidethecharging

Pagina 39 - 10.1.1AboutR410ARefrigerant

10.3. REFRIGERANTPIPINGWORKWhenworkingwithrefrigerantpiping,thefollowingpointsmustbecarefullyobserved:nomoistureoddustmustbeallowedtoenterthepiping,an

Pagina 40 - NecessaryTools

2.ProcedureandprecautionsforflareconnectionTable11R410AflaringdimensionsNominaldiameter(in)Outsidediameter(mm)Wallthickness(mm)A(mm)R410Aflaringtool,c

Pagina 41 - 10.2.2.R410ATools

PrecautionsBesuretoreadtheinstructionsforthevacuumpump,vacuumpumpadaptorandmanifoldgaugepriortouse,andfollowtheinstructionscarefully.Makesurethattheva

Pagina 42

10.4.2.Transferring(UsingNewRefrigerantPiping)1.Removingtheunita.CollectingtherefrigerantintotheoutdoorunitbypumpingdownTherefrigerantcanbecollectedin

Pagina 43

5.Settherefrigerantcylinderontotheelectronicscale,thencorrectthehosethecylinderandtotheconnectionportfortheelectronicscale.(1)(2)Precaution:Besuretose

Pagina 44 - 10.3. REFRIGERANTPIPINGWORK

<BrazingMethodforPreventingOxidation>1.Attachareducingvalvetothenitrogengascylinder.2.Attachareducingvalvetothenitrogengascylinder.3.Applyasealo

Pagina 45

OutdoorUnit5Anti-reverseProtectionToprotectthecompressorfromreverserotationwhenpoweroffsuddenly.OverloadProtector60-secondsTestOperationControlOncethe

Pagina 46 - RefrigerantPiping)

5011Disassemblyoftheparts1.Opentheintakegrilleandpullittothehorizontalposition.(Fig.1)2.Pulluptheintakegrilleuntilitfallsoff.(Fig.2)RemovalProcedureFo

Pagina 47

51CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE2Removethecoverofcontrolboardandholder.RemovalProcedureForElectronicController4.ReleasetheleadwireCN-FM,CN-

Pagina 48 - 10.4.6.Brazing

52CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKERemovalProcedureForCrossFlowFanRemotecontrolresetIfthedisplayischaoticorcannotbeadjusted,Removethebacklidof

Pagina 49 - 10.4.7.ServicingTips

53Inordertodiagnosemalfunctions,makesurethattherearenoelectricalproblemsbeforeinspectingtherefrigerationcycle.Suchproblemsincludeinsufficientinsulatio

Pagina 50 - 11Disassemblyoftheparts

54ConditionoftheairconditionerInsufficientrefrigerant(gasleakage)CloggedcapillarytubeShortcircuitintheindoorunitHeatradiationdeficiencyoftheoutdooruni

Pagina 51

55ThermostatcharacteristicsSoftdrymodeCoolingonCoolingoffsettemperature=SoftDryoffSoftDryon1.5indifference1.0 indifferenceTemperaturesettingCoolingmod

Pagina 52 - FixingScrew

CS/CU-UW9GKE3032343638404244230V17161514131.000.950.900.853.02.82.62.42.26.05.04.03.0Coolingcharacteristics56Outdoortemp()[Condition]Roomtemp:27/19Coo

Pagina 53 - 12TroubleshootingGuide

303234363840424417161514130.700.650.600.550.503.83.63.43.23.02.87.06.05.04.0Outdoortemp()[Condition]Roomtemp:27/19Coolingoperation:athighspeedPipingle

Pagina 54

CS-UW9GKE14ExplodedView5838331342251532141723830312724293130117102119262016131862212373635CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE34IIIIIIOIOI

Pagina 55 - 13TechnicalData

15ReplacementPartsList59CS-UW9GKENote:1.AllpartsaresuppliedfromPHAAG,P.R.China.2."*"markedpartsarerecommendedtobekeptinstock.CS-UW9GKE/CU-UW

Pagina 56 - Operationcharacteristics

63ProductSpecificationsCS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKECoolingCapacityHeatingCapacityMoistureRemovalPowerSourceAirflowMethodAirCirculationInd

Pagina 57

16ExplodedView604532672211272019182914810911315161217282524232135263330323134CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE

Pagina 58 - 14ExplodedView

17ReplacementPartsList61Note:1.AllpartsaresuppliedfromPHAAG,P.R.China.2."*"markedpartsarerecommendedtobekeptinstock.CS-UW9GKE/CU-UW9GKE/CS-U

Pagina 59 - 15ReplacementPartsList

1343522329162183031252226282711710241814136191217201526CS-UW12GKE18ExplodedView34303362CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE3132OIOIIIIIII

Pagina 60 - 16ExplodedView

19ReplacementPartsListCS-UW12GKENote:1.AllpartsaresuppliedfromPHAAG,P.R.China.2."*"markedpartsarerecommendedtobekeptinstock.63CS-UW9GKE/CU-U

Pagina 61 - 17ReplacementPartsList

353234334532672725262437221128212031138109116171530291418CU-UW12GKE20ExplodedView361864CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKE

Pagina 62 - 18ExplodedView

21ReplacementPartsListCU-UW12GKENote:1.AllpartsaresuppliedfromPHAAG,P.R.China.2."*"markedpartsarerecommendedtobekeptinstock.65CS-UW9GKE/CU-U

Pagina 63 - 19ReplacementPartsList

7CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKESpecificationsaresubjecttochangewithoutnoticeforfurtherimprovement.HeatExchangerDescriptionTubeMaterialFinTy

Pagina 64 - 20ExplodedView

8CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKECoolingCapacityHeatingCapacityMoistureRemovalPowerSourceAirflowMethodAirCirculationIndoorAir(low)IndoorAir(m

Pagina 65 - 21ReplacementPartsList

9CS-UW9GKE/CU-UW9GKE/CS-UW12GKE/CU-UW12GKESpecificationsaresubjecttochangewithoutnoticeforfurtherimprovement.*60gforairpurgingisnotincluded.HeatExchan