Important:
• Ifopenwiringisconducted,besuretouseconduitsandrunthecablesinsidethetubestopro-
tect the cables from direct sunlight.
• Whenconnectingtheconduitatthelateralorbottomposition,anyofthearrowmarksonthe
bracket shall be at the top.
• When connectingtheconduitupward,mountthecameraattachmentwiththearrowposition
on either left or right side.
<When connecting the conduit sideward or downward>
<When connecting the conduit upward>
• For installations on the wall, to prevent water from accumulating on the surface of the dehu-
midifying device (
page 13), do not connect it at the upper side.
If water remains inside, the dehumidifying device cannot function properly.
• Installationworkshallbesuchthatthereisnointrusionofwaterintothearchitecturethrough
the conduits having been joined.