452 ON_SCREEN DISPLAY
You can set the display contents in this menu.
452 OH-SCREEN DISPLAY
VIDEO
INPUT DISP.:
ON OFF
TITLE DISP. :
ON OFF
CLOCK
DISP. :
ON
OFF
TIiMOVE
SELECT ESC : PRV
1. Open the 452 ON_SCREEN DISPLAY menu.
2. Move the cursor to VIDEO INPUT DISP. and select ON
or OFF with the or ► button. The default setting is
ON.
ON: Enables the display of the currently designated
video input.
OFF: Disables the display.
3. Move the cursor to TITLE DISP. and select ON or OFF
with the or ► button. The default setting is ON.
ON: Enables the title display.
OFF: Disables the display.
4. Move the cursor to CLOCK DISP. and select ON or
OFF with the or ► button. The default setting is ON.
ON: Enables the time and date display.
OFF: Disables the display.
453 CABLE COMPENSATION (Transmitter only)
Picture quality is lowered as long as the cable is extended
between the transmitter and the camera. Compensation is
applied to the transmitter in three degrees with assumption
that RG'59/U, BELDEN 9259 or equivalent cable is used.
The default setting is S.
453 CABLE COMPENSA'
CAMERAl; S
M L
CAMERA2:
S
M L
CAMERA3: S M L
CAMERA4: S и L
T4^:MOVE
SELECT ESC: PRV
1. Open the 453 CABLE COMPENSATION menu.
2. Move the cursor to CAMERA 1 and select S, M or L
with the or ► button.
S (Short): Up to 400 m (1 300 ft)
M (Middle): From 400 m {1 300 ft) to 700 m (2 300 ft)
L (Long): From 700 m (2 300 ft) to 900 m (3 000 ft)
3. Repeat above step for the remaining cameras.
460 ALARM (Transmitter only)
Alarm sensors are connected with a transmitter unit, and
are located at where the camera aims or associated
places. If a connected sensor operates, the transmitter unit
will notify the Control site of the alarm activation during
standby mode. Then the unit starts communication to trans
mit image and audio. The 460 ALARM menu lets you select
and set up the 461 ALARM SETUP, 462 to 464 ALARM
DIALING TABLES and 465 ALARM PORT SETUP. For more
information, see SENSOR OPERATION in APPENDIX.
1. Open the 460 ALARM menu.
460 ALARM
461 ALARM SETUPJ,
462 ALARM DIALING TABLEll
463 ALARM DIALING TABLE21
464 ALARM DIALING TABLE3.T
465 ALARM PORT SETUP4^
T4:MOVE ENT:SELECT ESC:PRV
2. Select 461, 462, 463, 464 or 465 with the A or ▼ but
ton, then press the ENTER.
The selected menu appears.
461 ALARM SETUP (Transmitter only)
This setup is applied only to the transmitter.
1. Open the 461 ALARM SETUP menu.
461 ALARM SETUP
ALARM TYPE; LEVEL EDGE(OPEN CLOSE)
ALARM AUTO DISC : ON OFF
ALARM AUTO DISC TIMER : 060S
ALARM DIALING TIME TABLE;
TABLE DAY TIME
1 MOH-SUH 00:00-00:00
2 MON-FRl 08:30-17:00
3 FRI-MON 17:00-08:00
ENT:DAY INC. DEL;CLR
T4.Η>:MOVE ESC:PRV
Move the cursor to ALARM TYPE and select either
LEVEL or EDGE (OPEN CLOSE) with the ^ or ► but
ton. The default setting is EDGE (CLOSE).
43