• Control Operation
Type in the location bar http://192.168.010/ . The 192.168.010 in the URL may vary depending on the WJ-NT204 settings.
Type the identical address to that the WJ-NT204 is set to. The WJ-HD500 OPERATION VIEW window appears.
Cwy^i^A 0 ziu I K
r qw*»p: 4twi tr^MVnC f.'e, L1 ^
<D
I Wn>ETEU/ FAJt IJEAP. AUTO CLOSE orni FCEiET ON
83li
OFF
si
< >
fid
SI H
[|p|
SI
ii'
...
"zi
séI
© WJ-NT204 CAMERA SELECT
These buttons select the input to VIDEO IN 1-4 on the
WJ-NT204 to display it in the Image Display area.
® INPUT from WJ-HD500
Switches the window from that of WJ-NT204 control to
that of WJ-HD500 control.
Clicking this opens the 16-button panel on the left win
dow enabling the input selection to the video WJ-
HD500, and the control panel for operating the WJ-
HD500 on the bottom center.
© WJ-NT204 ALARM LIST
Displays the alarm list activated on the WJ-NT204.
© ALARM RESET
Resets the alarm mode activated on the WJ-NT204.
© CAMERA PRESET REGISTRATION
Registers the presently displayed image position of the
camera directly connected to the WJ-NT204.
Manipulate the camera to the desired position, then
select the preset number with the pull-down button.
Click the SET button to register the position.
© Camera Control Buttons
These buttons control the combination camera desig
nated with WJ-NT204 CAMERA SELECT button for
pan/tilt, zoom, focus and auto-pan.
© Status Window
Displays information when an alarm is activated on the
WJ-HD500.
© Image Display
Displays the live camera image or playback image on
the WJ-HD500.