This is a system exampie that the WJ-NT204 transmitter has none of directiy connected combination cameras whiie it has com
bination cameras connected indirectiy via WJ-MP204 and WJ-HD500,
■ WJ-HD500 Digital Disk Recorder Control (PS.Data)
• Connections
1. Connect MULTiSCREEN OUT on the rear of the WJ-HD500 to ViDEO IN on the WJ-NT204 \with a BNC attached coaxiai
cabie,
2. Connect 16 Combination cameras to CAMERA iN 1-4 on WJ-MP204 unit #1 through #4 with coaxiai cabies,
3. Connect CAMERA OUT 1-4 on WJ-MP204 unit #1 through #4 to ViDEO iN 1-16 on the WJ-HD500.
4. Connect DATA terminais among WJ-MP204, WJ-HD500 and WJ-NT204 with RS-485 cabies and branch connectors.
Combination Camera 1-16
• Setup for Peripheral Devices
1. Address Setup
Unit addresses must be set as foiiow.
Unit Name
WJ-HD500
WJ-MP204 #1
WJ-MP204 #2
WJ-MP204 #3
WJ-MP204 #4
Unit Address
1 (set in its own setup menu)
2 (set with UNiT switch on its front panel)
3 (set with UNiT switch)
4 (set with UNiT switch)
5 (set with UNiT switch)
2. PS.Data Communication Parameter Setup
Every unit must be set to the same parameter in their own setup menus.
(For example, BAUD RATE: 9600 bps, DATA BIT: 8 bits, STOP BIT: 1 bit, PARITY: NONE)
3. Input Assignment
For WJ-MP204 units, open CAMERA CONFIG menu on each unit, and set CAM NO. (camera numbers) as follows.
Unit Name
WJ-MP204 #1
WJ-MP204 #2
WJ-MP204 #3
WJ-MP204 #4
CAM NO.
1CH through 4CH
5CH through 8CH
9CH through 12CH
13CH through 16CH
For more information, refer to the manual included in each unit.
• Setup for WJ-NT204 Transmitter
1. On the ADMINISTRATOR SETUP PAGE, click the MODE SETUP button to open the MODE SETUP window.
2. Select either H.323/H.261 or JPEG in the MAIN PAGE DEFAULT MODE & INDEX FILE SELECT area.
Make the CONTROL SETUP as follows.
CAM CONTROL: PS Data
AUX SYSTEM CONTROL; HD500
Default Unit Address: 1
Click SET & REBOOT. The WJ-NT204 transmitter will restart. Confirm the transmitter has restarted.
3. On the ADMINISTRATOR SETUP PAGE, click the SERIAL PORT button to open the SERIAL PORT SETUP window.
In the window, select PS.Data for TYPE, and set communication parameters the same as that other devices are set to.