15.1.4. To remove the Discharge Grille
Pull out the Drain Hose (behind the Discharge Grille) from
outlet to remove the Discharge Grille. (Fig. 8)
Fig. 8
15.1.5. To remove the Control Board
Release the 3 screws. (Fig. 9)
• By pressing down the hook at the left side of Control Board,
you will be able to remove the Control Board. (Fig. 9)
Fig. 9
15.1.6. To remove the Cross Flow Fan and Indoor Fan Motor
Remove the screw at the Cross Flow Fan. (Fig 10)
Reminder:- To reinstall the Fan Motor, please adjust the
connector location to 45° with Fan Motor before fixing
Control Board. (Fig. 10)
Remove the Bearing. (Fig. 11)
Remove the screw at the left of the Evaporator. (Fig. 11)
Press the Hold to the left side then you can release the
Evaporator. (Fig. 11)
Fig. 10
Fig. 11