Panasonic CSYE12MKX Instrucciones de operaciones Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 47
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
30
2nd & following judgment (every 15 minutes after 1st judgment)
JUDGE CONDITION REFERANCE MODE
If indoor intake temp – Remote control temp
setting +3
¾ Cool mode if previously is Cool /
Heat mode
¾ Dry mode if previously is Dry mode
If -2 indoor intake temp. – Remote control
Temp. setting < +3
Maintain current mode
If indoor intake temp. – Remote control
temp. setting < -2
Heat mode
12.2 Indoor Fan Motor Operation
Basic Rotation Speed
i. Manual Fan speed
Fan motor’s number of rotation is determined according to remote control setting.
Remote control O O O O O QUIET
Model
Tab Hi Me+ Me Me- Lo QLo
COOLING(rpm) 1070 980 900 820 740 610
CS-YE9MKX
HEATING(rpm) 1070 990
910 830 750 640
COOLING(rpm) 1170 1070 990 910 830 610
CS-YE12MKX
HEATING(rpm) 1200 1110 1050 990 930 700
COOLING(rpm) 1250 1110 1010 910 810 750
CS-YE18MKX
HEATING(rpm) 1350 1140 1040 940 840 750
ii. Auto Fan Speed (Cooling, Soft Dry Mode)
According to room temperature and setting temperature, indoor fan speed is determined automatically.
The indoor fan will operate according to pattern below.
Fan speed
Higher
Medium
Lower
A b c d e f g h a b
B. Feedback control
• Immediately after the fan motor started, feedback control is performed once every second.
• During fan motor on, if fan motor feedback 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error
counter increases, fan motor then stops and restarts. If the fan motor counter becomes 7 times, then H19 - fan motor
error is detected. Operation stops and cannot on back.
12.3 Outdoor Fan Motor Operation
Outdoor fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30
seconds after compressor stops operation.
Intake temp.- setting temp.
DRY COOL HEAT
-
6
-
5
-
4
-
3
-
2
-
10 123456
MAINTAIN
CURRENT MODE
COOL/DRY HEAT
Intake temp.- setting temp.
-
6
-
5
-
4
-
3
-
2
-
10123456