REDUDANT section
This section assigns the RS232C Port for the redundant communication. The RS232C Port cannot be
shared between the redundant communication and serial alarm interface.
[REDUNDANT]
***{ The RS232Port can be used as redundant communication, }
***{ if Backup CPU is checked in the Admin Console. }
***{ If no check, the port can be used for serial alarm when }
***{ Admin Console set the RS232C Controller. }
***{ Note: }
***{ The RS232Port should not share the RS232C Controller }
***{ defined in the Admin Console. }
***{ The RS232Port starts with "0", while RS232C Controller }
***{ in the Admin Console starts with "1". }
***{Format:RS232Port=<port#> }
***{0=firstRS232CPortofyourserver }
***{1=secondRS232CPortofyourserver(ifexisting) }
***{2=thirdRS232CPortofyourserver(ifexisting) }
RS232Port=0
TIMELINE section
This section allow user to change some settings for the ASM970 Client Software Time-Line feature.
[TIMELINE]
***{ This section allow user to change polling frequency of }
***{ retrieving the DVR and alarm information for the ASM970 Client Software }
***{ Time-Line feature. }
***{Format:TimeLine=<Minutes>,<Days>,<Model> }
***{Minutes=FrequencytoretrievefromDVR(5-30min) }
***{Days=daystosaveonHD(1-9999) }
***{Mode=0-off }
***{1–on(default) }
TimeLine=10,7,1
***{ This section allow user to change delete timing }
***{ of saving DVR and alarm information in ASC970. }
***{Format:DeleteTime=<Hour>}
***{Hour=Timetodeletethesavinginformation(00:00–23:59) }
DeleteTime=02:00
Alive Monitoring section
This section allow user to change some settings for the Alive Monitoring feature.
[ALIVEMONITORING]
***{ This section allow user to change the number of alive monitoring}
***{ of devices(Camera and Recorder) at a time.}
***{Format:CamAliveMonitoringNum=<MaxNumber>}
***{MaxNumber=NumberofalivemonitoringatatimeforCamera(1-256)}
***{Format:RecAliveMonitoringNum=<MaxNumber>}