How to use the terminals of the ALARM/CONTROL connector
This connector is used when connecting an external device such as a sensor that outputs alarm signals or when installing an
external alarm device such as a buzzer or a lamp. The connector to be used should be compatible with the pin array.
Pin array
The pin array is different from other Panasonic recorders. Make sure
that the connection is correct referring to the following.
Pin No. Signal Operation Remarks
1 Alarm input 1 Event action will be performed according to the
settings.
Make contact input
2 Alarm input 2
3 Alarm input 3
4 Alarm input 4
5 Alarm input 5
6 Alarm input 6
7 Alarm input 7
8 Alarm input 8
9 Alarm input 9
10 Network error output* Signal output upon detection of a broken Ethernet
link
Open collector output
24 V DC max., –100 mA
11 Alarm reset input Canceling the alarm display Make contact input
12 N/A
13 Signal ground
14 Signal ground
15 Face matching output Signal output at the occurrence of a face
matching alarm
Open collector output
24 V DC max., –100 mA
16 HDD error output* Signal output upon detection of an HDD error
17 Camera error output Signal output upon detection of a camera error
18 Recorder error output* Signal output upon detection of a recorder error
19 Recording error
output*
Signal output upon detection of a recording error
20 Time adjustment
signal input
According to the signal input from the other
device, the time of this recorder will be adjusted
to the hour (00 minutes 00 seconds).
Make contact input
21 Alarm output Alarm signal will be supplied at an event
occurrence (Except for a face matching alarm)
Open collector output
24 V DC max., –100 mA
22 N/A
23 N/A
24 N/A
25 +5 V output +5 V output 200 mA max.
* Refer to the "About the error logs and the network logs" (☞ Operating Instructions (PDF)) for further information about each
error output.
About the connector