38
Indoor Unit
Outdoor Unit
Test conditions
1. Cooling: Indoor Dry Bulb Temp. (°C) 27 Outdoor Dry Bulb Temp. (°C) 35
Wet Bulb Temp. (°C) 19 Wet Bulb Temp. (°C) 24
Heating: Indoor Dry Bulb Temp. (°C) 20 Outdoor Dry Bulb Temp. (°C) 7
Wet Bulb Temp. (°C) 12 (MAX) Wet Bulb Temp. (°C) 6
2. Standard piping length: 7.5m (Includes Indoor Unit piping length).
Model
CS-RE9JKX
CU-RE9JKX
CS-RE12JKX
CU-RE12JKX
CS-RE15JKX
CU-RE15JKX
COOL HEAT COOL HEAT COOL HEAT
Single, 230V, 50Hz Single, 230V, 50Hz Single, 230V, 50Hz
Power/Current
[kW] 0.700 0.820 1.010 1.120 1.260 1.540
[A] 3.45 3.70 4.70 5.20
6
.
05 7
.
10
Refrigerant
[k
g
]
R410A
0.810
R410A
0.970
R410A
0.970
Cooling Capacity
[kW] 2.500 3.500 4.200
Heating Capacity
[kW] 3.300 4.250 5.300
Noise Level
JIS C 9612
[<70 dB(A)]
[dB(A)]
42 42 42 42 46 47
Conditions
1m Distance
Max. cooling/
heating
operation
47 48 48 50 50 51
Sound power
level
[dB(A)]
53 53 53 53 57 58
60 61 61 63 63 64
Air Circulation
[m
3
/min.] 13.8 13.8 13.8 14.5 14.4 15.3
Product Weight
[k
g
]
9.0 9.0 9.0
28 30 36
Dimensions (L x W x H)
[mm]
848 × 204 × 290
780 × 289 × 540
kg
PRODUCT SPECIFICATION PRODUCT SPECIFICATION
F566761_EN1.indd 章节1:38F566761_EN1.indd 章节1:38 2008-12-10 8:47:422008-12-10 8:47:42