When the memory does not allow new signal registration because it is full
• When a total of 64 signals has already been registered and the memory is full, inputting a new signal and pressing
the MENU button on the remote control unit or the projector operating panel will display the overwriting registration
screen below. In this case, to register the new data, an existing signal will be cleared and overwriting with the new
data.
Overwriting registration procedure
Press the MENU button. ... The overwriting registration screen will be displayed.
Press the ENTER button. ... The SIGNAL LIST screen will be displayed.
• The memory numbers are from A1 to H8. (64 type of memory numbers, each
from A to H has eight memory numbers each.)
Press the UP ( )and DOWN ( ) arrow buttons to select the signal to be
cleared.
Press the ENTER button. ... The SIGNAL STATUS screen will be displayed.
• If not clearing the existing signal, press the MENU button to return the display
to the SIGNAL LIST screen.
Press the ENTER button.
• The clearing operation is complete and the SIGNAL STATUS screen will be
displayed. The contents of the new signal will be displayed for each item.
For the remainder of this registration procedure, follow on the previous page.
NEW SIGNAL INPUT
MEMORY FULL!!
OVERWRITE OLD DATA?
YES : ENTER
NO : MENU
SIGNAL LIST
NAME INPUT SS
nn:* 1 n-n
nn:* 2 n-n
nn:* 3 n-n
nn:* 1 n-n
nn:* 2 n-n
nn:
nn:<NO ENTRY> −  −
nn:<NO ENTRY> −  −
NEXT PAGE
SELECT :
DELETE : ENTER
EXIT : MENU
SIGNAL STATUS
NAME:XGA85-A4
OVERWRITE?
MEMORY-No. :A4
S.S.No. :1−2
INPUT No, :1
fH :68.70 kHz
fV :85.00 Hz
SYNC STATE :H(POS)
V(POS)
75 ohm
YES : ENTER
NO : MENU
SIGNAL STATUS
NAME:XGA85-A4
MEMORY-No. :A4
S.S.No. :1−2
INPUT No, :1
fH :68.70 kHz
fV :85.00 Hz
SYNC STATE :H(POS)
V(POS)
75 ohm
POSITION :
SELECT :
SET : ENTER
CLEAR : STD
EXIT : MENU