10. Installation Instruction
IMPORTANT (only for S18NKUA)
This product has been designed and manufactured to meet ENERGY STAR® criteria for energy efficiency when
matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to
archive rated capacity and efficiency. Installation of this product should follow the manufacturer’s refrigerant
charging and air flow instructions. Failure to confirm proper charge and airflow may reduce energy
efficiency and shorten equipment life.
10.1.1 Select the Best Location
10.1.1.1 Indoor Unit
Do not install the unit in excessive oil fume areas
such as kitchens, workshops etc.
There should not be any heat source or steam
near the unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near a doorway.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit
shall be at least 8.2 ft.
10.1.1.2 Outdoor Unit
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
Do not place any obstacles which may cause a
short circuit of the discharged air.
If piping length is over the [piping length for
additional gas], additional refrigerant should be
added as shown in the table.
Recommended installation height for outdoor unit
should be above the seasonal snow level.
Example: For S18NKUA
If the unit is installed at 41 ft distance, the quantity of
additional refrigerant should be 2.46 oz .... (41 - 32.8)
ft × 0.3 oz/ft = 2.46 oz.
10.1.2 Indoor/Outdoor Unit Installation
Diagram
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - 10. Installation Instruction

19 10. Installation Instruction • IMPORTANT (only for S18NKUA) This product has been designed and manufactured to meet ENERGY STAR® criteria for ener

Pagina 2 - Install a Sleeve of Piping

20 10.1.3 Indoor Unit 10.1.3.1 How to Fix Installation Plate The mounting wall must be strong and solid enough to prevent if from the vibration.

Pagina 3

21 10.1.3.3 Indoor Unit Installation 10.1.3.4 For the right rear piping 10.1.3.5 For the right bottom piping 10.1.3.6 For the embedded piping

Pagina 4

22 10.1.3.7 Connect the Cable to the Indoor Unit 1. The inside and outside connecting cable can be connected without removing the front grille. 2

Pagina 5

23 10.1.3.8 Wire Stripping and connecting requirement 10.1.3.9 Cutting and flaring the piping 1 Please cut using pipe cutter and then remove the

Pagina 6

24 10.1.4 Outdoor Unit 10.1.4.1 Install the Outdoor Unit • After selecting the best location, start installation to INDOOR/OUTDOOR UNIT INSTALLATION

Pagina 7

25 10.1.4.3 Evacuation of the equipment WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the follo

Pagina 8 - 10.1.4.5 Piping Insulation

26 9. Secure the wire onto the control board with the holder (clamper). 10. After completing wiring connections, reattach the particular plate and