103 Location of Controls and Components3.1. Indoor Unit3.2. Outdoor Unit3.3. Remote Control
114 Dimensions4.1. Outdoor Unit4.1.1. CU-E9GFE-2 CU-E12GFE-2
124.1.2. CU-E18GFE-2
135 Refrigeration Cycle Diagram5.1. CS-E9GFEW-2 CU-E9GFE-2CS-E12GFEW-2 CU-E12GFE-2 If piping length is over rated length, additional refrigerant sho
145.2. CS-E18GFEW-2 CU-E18GFE-2 If piping length is over rated length, additional refrigerant should be added as shown in the table.ModelPiping sizeR
156 Wiring Connection Diagram6.1. Outdoor Unit6.1.1. CU-E9GFE-2 CU-E12GFE-2
166.1.2. CU-E18GFE-2
177 Electronic Circuit Diagram7.1. Outdoor Unit7.1.1. CU-E9GFE-2 CU-E12GFE-2
187.1.2. CU-E18GFE-2
197.1.3. Main Printed Circuit BoardCU-E9GFE-2 CU-E12GFE-2
21 Safety Precautions• Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.• Electrical work must be installed or serviced
207.1.4. Main Printed Circuit BoardCU-E18GFE-2
218 Disassembly and Assembly Instructions8.1. Outdoor Unit8.1.1. CU-E9GFE-2 CU-E12GFE-21. Remove the 3 screws of the Top Panel.Fig. 132. Remove the 6
228.1.2. CU-E18GFE-21. Remove the 4 screws of the Top Panel.Fig. 192. Remove the 10 screws of the Front Panel.Fig. 203. Remove the Top Cover of the El
239 Technical Data9.1. Operation CharacteristicsCS-E9GFEW-2 CU-E9GFE-2
27CS-E12GFEW-2 CU-E12GFE-2
317. After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant conta
30
31CS-E18GFEW-2 CU-E18GFE-2
32
34
359.2. Sensible Capacity ChartO CS-E9GFEW-2 CU-E9GFE-2O CS-E12GFEW-2 CU-E12GFE-2O CS-E18GFEW-2 CU-E18GFE-2220V Outdoor Temp. (°C)230V 30°C35°C40°C4
3610 Exploded View and Replacement Parts List10.1. Indoor Unit
37REF. NO. PART NAME AND DESCRIPTION QTY. CS-E9GFEW-2 CS-E12GFEW-2 CS-E18GFEW-2 REMARKSB1 EVAPORATOR ASS'Y 1 CW1786554 ← CW1800652B1-7 FLARE NUT
38(Note)• All parts are supplied from ACBU, Japan. • "O" marked parts are recommended to be kept in stock.F10 CASING (LEFT) 1 CW1768075 ←←F1
3910.2. CU-E9GFE-2 CU-E12GFE-2Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not k
42 Specifications2.1. CS-E9GFEW-2 CU-E9GFE-2ITEM UNIT INDOOR UNIT OUTDOOR UNITPerformance Test Condition ISO5151COOL I NGCapacitykW 2.50 (0.80 ~ 3.0
40(Note)• All parts are supplied from PHAAM, Malaysia (Vendor Code: 061). • "O" maked parts are recommended to be kept in stock.REF. NO. PAR
4110.3. CU-E18GFE-2Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as stand
42(Note)• All parts are supplied from PHAAM, Malaysia (Vendor Code: 061). • "O" maked parts are recommended to be kept in stock.[PHAAM] Prin
51. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)and outdoor air temperatur
62.2. CS-E12GFEW-2 CU-E12GFE-2ITEM UNIT INDOOR UNIT OUTDOOR UNITPerformance Test Condition ISO5151COOL I NGCapacitykW 3.50 (0.80 ~ 3.80)kcal/h 3010
71. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)and outdoor air temperatur
82.3. CS-E18GFEW-2 CU-E18GFE-2ITEM UNIT INDOOR UNIT OUTDOOR UNITPerformance Test Condition ISO5151COOL I NGCapacitykW 5.00 (0.90 ~ 5.60)BTU/h 17100
91. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)and outdoor air temperatur