    / 143
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
© Panasonic Corporation 2015.
Order No: PAPAMY1501049CE
Indoor Unit Outdoor Unit
CS-E9RKUAW
CS-E12RKUAW
CS-E18RKUAW
CS-E24RKUAW
CU-E9RKUA
CU-E12RKUA
CU-E18RKUA
CU-E24RKUA
Destination
USA
Canada
Please file and use this manual together with the service manual for Model No. CU-2E18NBU and CU-5E36QBU, Order No.
PHAAM1111120A1 and PAPAMY1312037CE.
AUTO
COMFORT
MODE
POWERFUL /
QUIET
TEMP
OFF/ON
TIMER
SET
CANCEL
ON
OFF
123
AIR SWING
FANSPEED
SET CHECK CLOCK RESET
AC RC
ECONAVI
FAN
SPEED
AIR
SWING
AUTO
HEAT
COOL
DRY
FAN
/
TE
M P
O
FF/ON
TIMER
S
ET
CANCEL
ON
O
FF
1
2
3
C
HECK
AUTO
COMFORT
MODE
POWERFUL /
QUIET
TEMP
OFF/ON
TIMER
SET
CANCEL
ON
OFF
1
2
3
FANSPEED
SET CHECK CLOCK RESET
AC RC
ECONAVI
AUTO
HEAT
COOL
DRY
FAN
FAN
SPEED
AIR
SWING
AIR SWING
/
TE M P
O
FF/ON
R
S
ET
CANCEL
ON
O
FF
1
2
3
C
HE
K
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to
service or repair the products dealt with in this service information by anyone else could result in serious injury or death.
PRECAUTION OF LOW TEMPERATURE
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
Vista de pagina 0
1 2 3 4 5 6 ... 142 143

Indice de contenidos

Pagina 1 - Order No: PAPAMY1501049CE

© Panasonic Corporation 2015. Order No: PAPAMY1501049CE Indoor Unit Outdoor UnitCS-E9RKUAW CS-E12RKUAW CS-E18RKUAW CS-E24RKUAW CU-E9RKUACU-E12R

Pagina 2 - TABLE OF CONTENTS

10 Model Indoor CS-E18RKUAW CS-E24RKUAW Outdoor CU-E18RKUA CU-E24RKUA DRY BULB WET BULB DRY BULB WET BULB Indoor Operation Range (Cooling) (°F

Pagina 3 - 1. Safety Precautions

100 18.4.23 F91 (Refrigeration Cycle Abnormality) Malfunction Decision Conditions  The input current is low while the compressor is running at high

Pagina 4

101 18.4.24 F93 (Compressor Rotation Failure) Malfunction Decision Conditions  A compressor rotation failure is detected by checking the compressor

Pagina 5 - 2. Specification

102 18.4.25 F95 (Outdoor High Pressure Protection: Cooling or Soft Dry) Malfunction Decision Conditions  During operation of cooling or soft dry, w

Pagina 6

103 18.4.26 F96 (IPM Overheating) Malfunction Decision Conditions  During operating of cooling and heating, when IPM temperature data (212°F) is det

Pagina 7

104 18.4.27 F97 (Compress or Overheating) Malfunction Decision Conditions  During operation of cooling and heating, when compressor tank temperatur

Pagina 8

105 18.4.28 F98 (Input Over Current Detection) Malfunction Decision Conditions  During operation of cooling and heating, when an input over-current

Pagina 9

106 18.4.29 F99 (DC Peak Detection) Malfunction Decision Conditions During startup and operation of cooling and heating, when inverter DC peak data i

Pagina 10

107 WARNING19. Disassembly and Assembly Instructions High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capa

Pagina 11 - 3. Features

108 Figure 3 Figure 4 19.1.1.3 To remove discharge grille Figure 5 19.1.1.4 To remove control board Figure 6 CN-RMTCN-FMCN-STM1CN-MSENSCN-THC

Pagina 12 - 4.3 Remote Control

109 19.1.1.5 To remove cross flow fan and indoor fan motor Figure 7 Figure 8 Figure 9 14. Remove the screw that holdingthe cross flow fan and

Pagina 13 - 5. Dimensions

11 3. Features  Inverter Technology o Wider output power range o Energy saving o Quick Cooling o More precise temperature control  Environment

Pagina 14 - 1/32~1/16

110 Figure 10 Reminder: To reinstall the cross flowfan, ensure cross flow fan is in line asshown in fi

Pagina 15 - 5.2 Outdoor Unit

111 WARNING High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before p

Pagina 16 - 6.1 CU-E9RKUA CU-E12RKUA

112 19.2.1.3 To remove discharge grille Figure 5 19.2.1.4 To remove control board Figure 6 19.2.1.5 To remove cross flow fan and indoor fan mot

Pagina 17 - 6.2 CU-E18RKUA CU-E24RKUA

113 Figure 8 Figure 9 Figure 10 15. Remove the screw from theevaporator.16. Remove the bearing by pulling itout gently.19. Fan motor can be r

Pagina 18 - 7. Block Diagram

114 19.3 Outdoor Electronic Controller Removal Procedure 19.3.1 CU-E9RKUA CU-E12RKUA Caution! When handling electronic controller, be careful of el

Pagina 19

115 19.3.2 CU-E18RKUA CU-E24RKUA Caution! When handling electronic controller, be careful of electrostatic discharge. 1 Remove the 8 screws of the

Pagina 20 - 8. Wiring Connection Diagram

116 20. Technical Data Technical data provided are based on the air conditioner running under free frequency. 20.1 Cool Mode Performance Data Unit se

Pagina 21 - CONTROLLER

117 20.1.3 CS-E18RKUAW CU-E18RKUA Rated frequency (compressor speed is fixed during forced heating or cooling for capacity measurement and diagnosis

Pagina 22 - 8.2 Outdoor Unit

118 20.1.5 CS-E9RKUAW CU-E9RKUA Maximum Capacity Indoor (°C / °F) Outdoor (°C / °F) DB WB -20 (-4) -10 (14) 0 (32) 5 (41) TC SHC IP TC SHC

Pagina 23 - (YELLOW)

119 20.1.7 CS-E18RKUAW CU-E18RKUA Maximum Capacity Indoor (°C / °F) Outdoor (°C / °F) DB WB -20 (-4) -10 (14) 0 (32) 5 (41) TC SHC IP TC

Pagina 24 - 9.1 Indoor Unit

12 4. Location of Controls and Components 4.1 Indoor Unit 4.2 Outdoor Unit 4.3 Remote Control POWERTIMERECONAVIAUTOCOMFORTPOWERFULQUIETHorizonta

Pagina 25

120 20.2 Heat Mode Performance Data Unit setting: Standard piping length, Hi Fan, Heat mode at 86°F Voltage: 230V 20.2.1 CS-E9RKUAW CU-E9RKUA Rated

Pagina 26 - 9.2.1 CU-E9RKUA CU-E12RKUA

121 20.2.5 CS-E9RKUAW CU-E9RKUA Maximum Capacity Indoor (°C / °F) Outdoor (°C / °F) DB -20 (-4) -8.3 (17.06) 1.7 (35.06) 8.3 (46.94) 12 (53.6)

Pagina 27 - SUPPLY CIRCUIT

122 21. Service Data Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced heating mode.

Pagina 28 - 10. Printed Circuit Board

123 21.1.2 CS-E12RKUAW CU-E12RKUA 57.057.558.058.559.059.560.060.561.061.562.0-4 6 162636465666768696106116Outlet Air(°F)Out

Pagina 29 - CN-MSENS

124 21.1.3 CS-E18RKUAW CU-E18RKUA 52.054.056.058.060.062.064.066.068.0-4 6 162636465666768696106116Outlet Air(°F)Outdoor Air

Pagina 30 - 10.2 Outdoor Unit

125 21.1.4 CS-E24RKUAW CU-E24RKUA 48.049.050.051.052.053.054.055.056.057.058.059.060.0-4 6 162636465666768696106116Outlet Ai

Pagina 31

126 21.2 Heat Mode Outdoor Air Temperature Characteristic Condition - Indoor room temperature: 68°F Dry Bulb/-°F Wet Bulb - Unit setting: Standard pi

Pagina 32

127 21.2.2 CS-E12RKUAW CU-E12RKUA 88.090.092.094.096.098.0100.0102.0104.0106.0108.0110.0-4 1 6 11 16 21 26 31 36 41 46 51 56

Pagina 33 - Diagram

128 21.2.3 CS-E18RKUAW CU-E18RKUA 88.090.092.094.096.098.0100.0102.0104.0106.0-4 1 6 11 16 21 26 31 36 41 46 51 56 61 66 71

Pagina 34 - 11.2 Indoor Unit

129 21.2.4 CS-E24RKUAW CU-E24RKUA 102.0104.0106.0108.0110.0112.0114.0116.0118.0120.0122.0-4 1 6 11 16 21 26 31 36 41 46 51 5

Pagina 35 - Shock absorber

13 5. Dimensions 5.1 Indoor Unit 5.1.1 CS-E9RKUAW CS-E12RKUAW 7/81-7/85-1/4Remote controlRemote control holder22-3/8AUTOCOMFORTMODEPOWERFUL/

Pagina 36 - Rear Side of Indoor Unit

130 21.3 Piping Length Correction Factor The characteristic of the unit has to be corrected in accordance with the piping length. 21.3.1 CS-E9RKUAW

Pagina 37 - RISK OF FIRE

131 21.3.2 CS-E18RKUAW CU-E18RKUA CS-E24RKUAW CU-E24RKUA Note: The graphs show the factor after added right amount of additional refrigerant.

Pagina 38 - 11.3 Outdoor Unit

132 22. Exploded View and Replacement Parts List 22.1 Indoor Unit 22.1.1 CS-E9RKUAW CS-E12RKUAW Note The above exploded view is for the purpose o

Pagina 39 - 11.3.2.4 Gas Leak Checking

133 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-E9RKUAW CS-E12RKUAW REMARK 1 CHASSIS COMPLETE 1 CWD50C1633 ← 2 FAN MOTOR 1 L6CB

Pagina 40 - 11.3.3.2 Piping Insulation

134 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-E9RKUAW CS-E12RKUAW REMARK 51 SHOCK ABSORBER ( L ) 1 CWG713386 ← 52 SHOCK ABSORBE

Pagina 41 - 12.1.2 Outdoor Unit

135 22.1.2 CS-E18RKUAW CS-E24RKUAW Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts a

Pagina 42 - 12.2 Indoor Unit

136 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-E18RKUAW CS-E24RKUAW REMARK 1 CHASSIS COMPLETE 1 CWD50C1637 ← 2 FAN MOTOR 1 L6C

Pagina 43

137 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CS-E18RKUAW CS-E24RKUAW REMARK 49 REMOTE CONTROL HOLDER 1 CWH361078 ← 50 BAG 1 CWG

Pagina 44

138 22.2 Outdoor Unit 22.2.1 CU-E9RKUA CU-E12RKUA Note The above exploded view is for the purpose of parts disassembly and replacement. The non-n

Pagina 45

139 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CU-E9RKUA CU-E12RKUA REMARK 1 CHASSIS COMPLETE 1 CWD50K2081A ← 2 FAN MOTOR BRACKET

Pagina 46 - 12.3 Outdoor Unit

14 5.1.2 CS-E18RKUAW CS-E24RKUAW 7/81-7/85-1/4Remote controlRemote control holder22-3/8AUTOCOMFORTMODEPOWERFUL/QUIETTEMPOFF/ONTIMERSETCAN

Pagina 47 - 12.3.2.4 Gas Leak Checking

140 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CU-E9RKUA CU-E12RKUA REMARK 50 SOUND PROOF MATERIAL 1 CWG302292 ← 51 SOUND PROOF MAT

Pagina 48 - 12.3.3.2 Piping Insulation

141 22.2.2 CU-E18RKUA CU-E24RKUA Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are

Pagina 49 - 13. Operation Control

142 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CU-E18RKUA CU-E24RKUA REMARK 1 CHASSIS COMPLETE 1 CWD52K1228A ← 2 ANTI - VIBRATION B

Pagina 50

143 SAFETY REF. NO. PART NAME & DESCRIPTION QTY. CU-E18RKUA CU-E24RKUA REMARK 49 SHOCK ABSORBER ( R ) 1 CWG712880 ← 50 SHOCK ABSORBER

Pagina 51

15 5.2 Outdoor Unit 5.2.1 CU-E9RKUA CU-E12RKUA 5.2.2 CU-E18RKUA CU-E24RKUA <Side View><Side View> <Front View><Top View&

Pagina 52 - 13.5 Airflow Direction

16 6. Refrigeration Cycle Diagram 6.1 CU-E9RKUA CU-E12RKUA INDOOROUTDOORINTAKETEMP.SENSORPIPETEMP.SENSORINTAKETEMP.SENSORPIPET

Pagina 53 - A 68 ~ 112

17 6.2 CU-E18RKUA CU-E24RKUA INDOOR OUTDOORINTAKETEMP.SENSORPIPETEMP.SENSOR 1PIPETEMP.SENSOR 2INTAKETEMP.SENSORPIPETEMP.SENSOR

Pagina 54 - 13.9 Timer Control

18 7. Block Diagram 7.1 CS-E9RKUAW CU-E9RKUA CS-E12RKUAW CU-E12RKUA

Pagina 55 - 13.11 Indication Panel

19 7.2 CS-E18RKUAW CU-E18RKUA CS-E24RKUAW CU-E24RKUA

Pagina 56 - Remote control normal mode

2 TABLE OF CONTENTS 1. Safety Precautions ... 3 2. Specification ...

Pagina 57

20 8. Wiring Connection Diagram 8.1 Indoor Unit 8.1.1 CS-E9RKUAW CS-E12RKUAW MRECTIFICATIONCIRCUITCOMMU NICATIONCIRCUIT

Pagina 58

21 8.1.2 CS-E18RKUAW CS-E24RKUAW MREC T IF ICA T IO NCIRCUITCOMM UNICATIONCIRCUIT1W23BLAC303 (WH T)AC306 (BLK)AC3

Pagina 59 - 14.3 Heating Operation

22 8.2 Outdoor Unit 8.2.1 CU-E9RKUA CU-E12RKUA 5RS102XHA211.7411.7651.711CONNECTIONResistance of Compressor WindingsU-VU-WV-WL1 L21(BLACK

Pagina 60

23 8.2.2 CU-E18RKUA CU-E24RKUA NOIS E FILTERCIRCUITCOMMUNICATIONCIRCUITRECT IFIC ATIONCIRCUITREC TIFICATIONCIRCUITPFCCIRCUITSWITCHING POWERSUPPL

Pagina 61

24 9. Electronic Circuit Diagram 9.1 Indoor Unit 9.1.1 CS-E9RKUAW CS-E12RKUAW BZ201BZ5V_R20947IC201C2020.01uC20147uR2180ceJP201R210JP200R

Pagina 62

25 9.1.2 CS-E18RKUAW CS-E24RKUAW BZ201BZ5V_R20947IC201C2020.01uC20147uR2180ceJP201R210JP200R211JP203R212JP204POWERFUL/QUIET(oran g e /

Pagina 63 - Outdoor Air Temperature

26 9.2 Outdoor Unit 9.2.1 CU-E9RKUA CU-E12RKUA L1 L21(BLACK)2(BLACK)3(RED)TERMINAL BOARDGRNGRNGRNBLKBLKWHTWHT REDTO INDOOR UNITPOWER SUPPLYDAT

Pagina 64

27 9.2.2 CU-E18RKUA CU-E24RKUA NO IS E FILTERCIRCUITCOMMUNICATIONCIRCUITRE C T IF IC ATIONCIRCUITRE C T IF IC ATIONCIRCUITPFCCIRCUITSWITCHING

Pagina 65

28 10. Printed Circuit Board 10.1 Indoor Unit 10.1.1 Main Printed Circuit Board 10.1.2 Indicator Printed Circuit Board CN-RMTCN-FMCN-STM2(E18/24

Pagina 66

29 10.1.3 Comparator Printed Circuit Board CN-SENS1CN-SENS2CN-MSENS

Pagina 67 - E18RKUA, E24RKUA

3 CAUTION WARNINGWARNING 1. Safety Precautions  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.  Electrical work m

Pagina 68

30 10.2 Outdoor Unit 10.2.1 Main Printed Circuit Board 10.2.1.1 CU-E9RKUA CU-E12RKUA CN-DCFMFG1CN-STMCN4CN5CN-TANKCN-THCN-HOTCURRENTTRANSFORMER(

Pagina 69

31 10.2.1.2 CU-E18RKUA CU-E24RKUA CN-SCN-COMCN-TH1CN-EVCN-DISCN-HTCN-HO TAC-BLKAC-WHTPOWERTRANSISTOR(IPM)CURRENTTRANSFORMER(CT)DC-FM

Pagina 70 - 17. Servicing Mode

32 10.2.2 Noise Filter Printed Circuit Board 10.2.2.1 CU-E18RKUA CU-E24RKUA

Pagina 71

33 11. Installation Instruction (E9RK and E12RK) 11.1 Select the Best Location 11.1.1 Indoor Unit  Do not install the unit in excessive oil fume a

Pagina 72 - 17.3 Remote Control Button

34 11.2 Indoor Unit 11.2.1 How to Fix Installation Plate The mounting wall shall be strong and solid enough to prevent it from the vibration. The

Pagina 73 - 18. Troubleshooting Guide

35 11.2.3 Indoor Unit Installation 11.2.3.1 For the right rear piping 11.2.3.2 For the right bottom piping 11.2.3.3 For the embedded piping

Pagina 74

36 11.2.4 Connect the Cable to the Indoor Unit 1. The inside and outside connection cable can be connected without removing the front grille. 2. U

Pagina 75 - 18.2.2 To Make a Diagnosis

37 11.2.5 Wiring Stripping and connecting requirement 11.2.5.1 Cutting and flaring the piping 1 Please cut using pipe cutter and then remove the

Pagina 76 - 18.3 Error Code Table

38 11.3 Outdoor Unit 11.3.1 Install the Outdoor Unit  After selecting the best location, start installation according to indoor/outdoor unit instal

Pagina 77

39 11.3.2.3 Connecting the piping to outdoor multi Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare aft

Pagina 78 - 18.4 Self-diagnosis Method

4 CAUTIONWARNING 19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing r

Pagina 79

40 11.3.3.1 Connect the Cable to the Outdoor Unit 1. Remove Top panel. 2. Remove Control Board Cover (Resin and Metal). 3. Remove Plugs. 4. Fix the

Pagina 80 - Characteristics

41 12. Installation Instruction (E18RK and E24RK) 12.1 Select the Best Location 12.1.1 Indoor Unit  Do not install the unit in excessive oil fume

Pagina 81 - (Thermistor) Charateristics

42 12.2 Indoor Unit 12.2.1 How to Fix Installation Plate The mounting wall shall be strong and solid enough to prevent it from the vibration. The

Pagina 82

43 12.2.3 Indoor Unit Installation 12.2.3.1 For the right rear piping 12.2.3.2 For the right bottom piping 12.2.3.3 For the embedded piping

Pagina 83

44 12.2.4 Connect the Cable to the Indoor Unit 1. The inside and outside connection cable can be connected without removing the front grille. 2.

Pagina 84

45 12.2.5 Wiring Stripping and connecting requirement 12.2.5.1 Cutting and flaring the piping 1 Please cut using pipe cutter and then remove the

Pagina 85

46 12.3 Outdoor Unit 12.3.1 Install the Outdoor Unit  After selecting the best location, start installation according to indoor/outdoor unit instal

Pagina 86

47 12.3.2.3 Connecting the piping to outdoor multi Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare aft

Pagina 87

48 12.3.3.1 Connect the Cable to the Outdoor Unit 1. Remove control board cover (Resin and Metal). 2. Remove particular plate. 3. Remove plugs. 4.

Pagina 88

49 13. Operation Control 13.1 Basic Function Inverter control, which equipped with a microcomputer in determining the most suitable operation mode as

Pagina 89

5 2. Specification Model Indoor CS-E9RKUAW CS-E12RKUAW Outdoor CU-E9RKUA CU-E12RKUA Performance Test Condition ARI ARI Power Supply Phase, Hz Sin

Pagina 90

50 13.1.4.2 Automatic Operation (For Single Split Connection Only)  This mode can be set using remote control and the operation is decided by remot

Pagina 91

51 13.3 Indoor Fan Motor Operation 13.3.1 Basic Rotation Speed (rpm)  Manual Fan Speed [Cooling, Dry] o Fan motor’s number of rotation is determin

Pagina 92

52 13.5 Airflow Direction  There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vert

Pagina 93

53 13.5.3 Horizontal Airflow (CU-E18RKUA CU-E24RKUA)  Automatic horizontal airflow direction can be set using remote control; the vane swings left

Pagina 94

54 13.7 Quiet Operation (Heating)  Purpose o To provide quiet heating operation compare to normal operation.  Control condition o Quiet operatio

Pagina 95

55 13.10 Auto Restart Control  When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three

Pagina 96

56 2. Circuit Abnormal (Fix Output Lo) a. Abnormal judgment start condition. After ECONAVI and AUTO COMFORT Sensor unit power ON, and after press

Pagina 97

57  ECONAVI Start condition.  Press ECONAVI button.  ECONAVI Stop condition.  Press ECONAVI button again.  OFF Timer activates.  Press

Pagina 98

58 13.12.1 Human Activity Sensor Check Mode  To enable Human Activity sensor abnormality check mode, during ECONAVI operation ON:  During ECON

Pagina 99

59 14. Operation Control (For Multi Split Connection) During multi split connection, indoor unit’s operation controls are same with single split conn

Pagina 100 - NO, gas amount is OK

6 Model Indoor CS-E9RKUAW CS-E12RKUAW Outdoor CU-E9RKUA CU-E12RKUA Outdoor Fan Type Propeller Propeller Material PP PP Motor Type DC (8 pol

Pagina 101 - -TurnOFFthepower

60 14.4 Automatic Operation (For Multi Split Connection Only)  This mode can be set using remote control and the operation is decided by remote con

Pagina 102

61 15. Protection Control (E9RK and E12RK) 15.1 Protection Control For All Operations 15.1.1 Restart Control (Time Delay Safety Control)  The comp

Pagina 103

62 15.1.5 Compressor Overheating Prevention Control  Instructed frequency for compressor operation will be regulated by compressor discharge tempera

Pagina 104

63 15.2 Protection Control For Cooling & Soft Dry Operation 15.2.1 Outdoor Air Temperature Control  The maximum current value is regulated whe

Pagina 105

64 15.2.5 Dew Prevention Control 1  To prevent dew formation at indoor unit discharge area.  This control will be activated if: o Outdoor air te

Pagina 106

65 15.2.6.3 Overload Protection Control  The compressor operating frequency is regulated in accordance to indoor heat exchanger temperature as shown

Pagina 107 - Procedures

66 16. Protection Control (E18RK and E24RK) 16.1 Protection Control For All Operations 16.1.1 Restart Control (Time Delay Safety Control)  The com

Pagina 108 - Figure 5

67 16.1.5 Compressor Overheating Prevention Control  Instructed frequency for compressor operation will be regulated by compressor discharge tempera

Pagina 109 - Figure 9

68  The compressor will be stopped at outdoor air temperature ≤ -4°F. The unit still operate within the temperature range. 16.2.2 Cooling Overloa

Pagina 110 - Figure 10

69 16.2.6.2 Outdoor Air Temperature Control  The Max current value is regulated when the outdoor air temperature rise above 57.2°F in order to avoi

Pagina 111

7 Model Indoor CS-E9RKUAW CS-E12RKUAW Outdoor CU-E9RKUA CU-E12RKUA DRY BULB WET BULB DRY BULB WET BULB Indoor Operation Range (Cooling) (°F / °

Pagina 112

70 17. Servicing Mode 17.1 Auto Off/On Button Auto OFF/ON Button pressed Auto OFF/ON Button pressed Auto OFF/ON Button pressed 5 sec 5 sec Au

Pagina 113

71 Press Auto OFF/ON button to toggle remote control receiving sound. - Short “beep”: Turn OFF remote control receiving sound. - Long “beep”: Turn O

Pagina 114 - 19.3.1 CU-E9RKUA CU-E12RKUA

72 17.3 Remote Control Button 17.3.1 SET Button  To check remote control transmission code and store the transmission code to EEPROM o Press “Set”

Pagina 115 - 19.3.2 CU-E18RKUA CU-E24RKUA

73 18. Troubleshooting Guide 18.1 Refrigeration Cycle System In order to diagnose malfunctions, make sure that there are no electrical problems befor

Pagina 116 - 20. Technical Data

74 18.1.1 Relationship between the condition of the air conditioner and pressure and electric current  Carry out the measurements of pressure, el

Pagina 117

75 18.2 Breakdown Self Diagnosis Function 18.2.1 Self Diagnosis Function (Three Digits Alphanumeric Code)  Once error occurred during operation, t

Pagina 118 - 20.1.5 CS-E9RKUAW CU-E9RKUA

76 18.3 Error Code Table Abnormality /Protection controlAbnormalityJudgementProtectionoperationProblem Check locationDiagnosisdisplay——noitarepolam

Pagina 119

77 Note: “○” – Frequency measured and fan speed fixed The memory data of error code is erased when the power supply is cut off, or press the Auto Sw

Pagina 120 - 20.2.1 CS-E9RKUAW CU-E9RKUA

78 18.4 Self-diagnosis Method 18.4.1 H11 (Indoor/Outdoor Abnormal Communication) Malfunction Decision Conditions  During startup and operation of c

Pagina 121 - 20.2.5 CS-E9RKUAW CU-E9RKUA

79 18.4.2 H12 (Indoor/Outdoor Capacity Rank Mismatched) Malfunction Decision Conditions  During startup, error code appears when different types of

Pagina 122 - 21. Service Data

8 Model Indoor CS-E18RKUAW CS-E24RKUAW Outdoor CU-E18RKUA CU-E24RKUA Performance Test Condition ARI ARI Power Supply Phase, Hz Single, 60 Single

Pagina 123

80 18.4.3 H14 (Indoor Intake Air Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heati

Pagina 124

81 18.4.4 H15 (Compressor Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the

Pagina 125

82 18.4.5 H16 (Outdoor Current Transformer) Malfunction Decision Conditions  An input current, detected by Current Transformer CT, is below thresho

Pagina 126 - 21.2.1 CS-E9RKUAW CU-E9RKUA

83 18.4.6 H19 (Indoor Fan Motor – DC Motor Mechanism Locked) Malfunction Decision Conditions  The rotation speed detected by the Hall IC during fan

Pagina 127

84 18.4.7 H23 (Indoor Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, th

Pagina 128

85 18.4.8 H27 (Outdoor Air Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, th

Pagina 129

86 18.4.9 H28 (Outdoor Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, t

Pagina 130

87 18.4.10 H30 (Compressor Discharge Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and h

Pagina 131

88 18.4.11 H32 (Outdoor Heat Exchanger Temperature Sensor 2 Abnormality) Malfunction Decision Conditions  During startup and operation of cooling a

Pagina 132 - 22.1 Indoor Unit

89 18.4.12 H33 (Unspecified Voltage between Indoor and Outdoor) Malfunction Decision Conditions  The supply power is detected for its requirement b

Pagina 133

9 Model Indoor CS-E18RKUAW CS-E24RKUAW Outdoor CU-E18RKUA CU-E24RKUA Outdoor Fan Type Propeller Propeller Material PP PP Motor Type DC Moto

Pagina 134

90 18.4.13 H36 (Outdoor Gas Pipe Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and heating, the temp

Pagina 135 - 46 47 48

91 18.4.14 H37 (Outdoor Liquid Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions  During startup and operation of cooling and he

Pagina 136

92 18.4.15 H59 (Human Activity Sensor Abnormality) Malfunction Decision Conditions  Feedback signal of human activity sensor. Malfunction Caused 

Pagina 137

93 18.4.16 H70 (Light Sensor Abnormality) Malfunction Decision Conditions  Feedback signal of light sensor. Malfunction Caused  Feedback value i

Pagina 138 - 22.2 Outdoor Unit

94 18.4.17 H97 (Outdoor Fan Motor – DC Motor Mechanism Locked) Malfunction Decision Conditions  The rotation speed detected by the Hall IC during f

Pagina 139

95 18.4.18 H98 (Error Code Stored in Memory and no alarm is triggered / no TIMER LED flashing) Malfunction Decision Conditions  Indoor high pressur

Pagina 140

96 18.4.19 H99 (Indoor Freeze Prevention Protection: Cooling or Soft Dry) Error Code will not display (no Timer LED blinking) but store in EEPROM Ma

Pagina 141

97 18.4.20 F11 (4-way Valve Switching Failure) Malfunction Decision Conditions  When indoor heat exchanger is cold during heating (except deice) or

Pagina 142

98 18.4.21 F17 (Indoor Standby Units Freezing Abnormality) Malfunction Decision Conditions  When the different between indoor intake air temperatur

Pagina 143

99 18.4.22 F90 (Power Factor Correction Protection) Malfunction Decision Conditions  To maintain DC voltage level supply to power transistor.  To