Panasonic KE30NKUA Manual de instalación

Busca en linea o descarga Manual de instalación para Sistemas de intercomunicación de la puerta Panasonic KE30NKUA. Panasonic KE30NKUA Installation Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
$/09(08*54+0:054,8;9,9:/,8,-80.,8(4:"
>:,84(2+0(3,:,85-9,8<0*,658:"
Split System Air Conditioner
 
INSTALLATION INSTRUCTIONS
NOTE
&
Contents
Page
IMPORTANT!
Please Read Before Starting .................................. 2
1. GENERAL .......................................................... 4
1-1. Tools Required for Installation (not supplied)
1-2. Accessories Supplied with Unit
1-3. Optional Copper Tubing Kit
1-4. Type of Copper Tube and Insulation Material
1-5. Additional Materials Required for Installation
2. INSTALLATION SITE SELECTION ................... 5
2-1. Indoor Unit
2-2. Outdoor Unit
3. HOW TO INSTALL THE INDOOR UNIT ........... 13
3-1. Remove the Rear Panel from the Unit
3-2. Make a Hole
3-3. Install the Rear Panel on the Wall
3-4. Removing and Installing the Grille
3-5. Shape the Indoor Side Tubing
3-6. Wiring Instructions
3-7. Wire Size and Length
3-8. Wiring Instructions for Inter-unit Connections
3-9. Mounting
3-10. Frame Fastening Method
3-11. Drain Hose
4. HOW TO INSTALL THE OUTDOOR UNIT ....... 23
4-1. Wiring Instructions for the Outdoor Unit
4-2. Routing the Tubing and Wiring
5. REFRIGERANT TUBING .................................. 24
5-1. Use of the Flaring Method
5-2. Flaring Procedure with a Flare Tool
5-3. Caution before Connecting Tubes Tightly
5-4. Connecting Tubing between Indoor and
Outdoor Units
5-5. Insulation of Refrigerant Tubing
5-6. Taping the Tubes
5-7. Finishing the Installation
6. AIR PURGING................................................... 26
Air Purging with a Vacuum Pump (for Test Run)
Basic Functions of the Service Valves
Pump Down
Service Valve Connections
7. REMOTE CONTROLLER INSTALLATION
POSITION ......................................................... 30
7-1. Mounting on a Wall
8. ADDRESS SWITCH .......................................... 31
8-1. Address Setting of the Remote Controller
Model Combinations
Combine indoor and outdoor units only as listed
below.
Model No.
Indoor Unit Outdoor Unit
CS-KE30NKU CU-KE30NKU
CS-KE36NKU CU-KE36NKU
Power Source:
60 Hz, single-phase, 230/208 V
Vista de pagina 0
1 2 3 4 5 6 ... 31 32

Indice de contenidos

Pagina 1 - INSTALLATION INSTRUCTIONS

$/09(08*54+0:054,8;9,9:/,8,-80.,8(4:">:,84(2+0(3,:,85-9,8<0*,658:"Split System Air Conditioner

Pagina 2 - Please Read Before Starting

1025-13/32"3/32"13-3/8"(11-15/16")16-15/16"Air IntakeAirdischarge39-1/4"27-7/32"7-1/32"35-15/16"28-15/16&

Pagina 3 - When Servicing

11Reference diagram for snow-proof duct Space requirements for setting CU-KE30NKU, CU-KE36NKU with STK-BDV80E0458358,#04.2,;40:049:

Pagina 4 - 1. General

120458358,0458358,0458358,0458358,0458358,0458358,#04.2,;40:049:(22(:0

Pagina 5

13Rear panelFig. 7cRear panelFig. 7bSet screw only for transportationFig. 6Rear panelmarksFig. 7a,-::;)04."0./::;)04."0./:8,(8:;)04.8,*53

Pagina 6 - )5;:*3

14IndoorsideOutdoorsideHole should be made at a slight downward slant to theoutdoor side.NOTEFig. 10Plastic coverINSIDE OUTSIDEWallSlightanglePVC pipe

Pagina 7 - )5;:5-:/,;40:/,0./:

153-4. Removing and Installing the GrilleBasically, these models can be installed and wired with-out removing the grille. If access to any internal p

Pagina 8 - Unit: inch

163-5. Shape the Indoor Side Tubing(1) Arrangement of tubing by directiona) Right or left tubingCut out the corner of the right/left frame with ahack

Pagina 9

173-7. Wire Size and LengthRegulations on wiring diameter differ from locality to locality. For field wiring requirements, please refer to your local

Pagina 10 - 4-23/32"

183-8. Wiring Instructions for Inter-unit Connections(1) Insert the inter-unit wiring (according to local codes)into the through-the-wall PVC pipe. R

Pagina 11

19When connecting each power wire to the correspondingterminal, follow the instructions “How to connect wiringto the terminal” and fasten the wire sec

Pagina 12

2IMPORTANT! Please Read Before StartingThis air conditioning system meets strict safety and operatingstandards. As the installer or service person, it

Pagina 13

203-9. Mounting(1) To install the indoor unit, mount the indoor unit ontothe 3 tabs on the upper part of the rear plate. (2) Hold down the air discha

Pagina 14 - Hole Dia

21Hole in wallBent partNarrow tubeWide tubeRear panelFig. 38Drain capDrain hoseClampFig. 39 Left-side tubing(1) Lead the tubing and drain hose throug

Pagina 15

22To unmount indoor unitPress the 2 marks on the lower part of the indoor unitand unlatch the tabs. Then lift the indoor unit andunmount. (Fig. 42)3-

Pagina 16

234. How to Install the Outdoor UnitFirst refer to Section 2. Installation Site Selection.4-1. Wiring Instructions for the Outdoor UnitRegulations o

Pagina 17 - %$"

245. Refrigerant Tubing5-1. Use of the Flaring MethodMany of the conventional split system air conditionersemploy the flaring method to connect refr

Pagina 18

255-4. Connecting Tubing between Indoor and Outdoor Unitsa) Tightly connect the indoor side refrigerant tubing exten-ded from the wall with the outdoo

Pagina 19 - Strip 3/8" (10 mm)

266. Air PurgingAir and moisture remaining in the refrigerant systemhave undesirable effects as indicated below. Therefore,they must be purged comple

Pagina 20 - Rear panel

27(5) With the vacuum pump still running, close the “Lo”knob of the manifold valve. Then stop the vacuumpump.(6) With the hex wrench, turn the valve s

Pagina 21 - Drain cap

28How to Test Run the Air ConditionerAfter turning on the power of the air conditioner, use theremote controller and follow the steps below to conduct

Pagina 22

29 Pump DownPump down means collecting all refrigerant gas in thesystem back into the outdoor unit without losing any ofthe gas. Pump down is used wh

Pagina 23 - *54+;0:

 8VHWKHIODUHPHWKRGIRUFRQQHFWLQJWXELQJ $SSO\UHIULJHUDQWOXEULFDQWWRWKHPDWFKLQJVXUIDFHVRIthe flare and union tubes before connecting them

Pagina 24 - 5. Refrigerant Tubing

30( $,3658(8?*544,*:054#*8,=04@:;849)?/(4+0.*) $5-(9:,4:/,-2(8,4;:9(662?96,*0-0,+:587;,(9$()2,(4+0.+Fig. 60c

Pagina 25 - Apply putty here

318. Address Switch8-1. Address Setting of the Remote ControllerThe address can be set in order to prevent interferencebetween remote controllers wh

Pagina 27

41. GeneralThis booklet briefly outlines where and how to install theair conditioning system. Please read over the entire setof instructions for the

Pagina 28

51-5. Additional Materials Required for Installation1. Refrigeration (armored) tape2. Insulated staples or clamps for connecting wire(See local codes

Pagina 29 - Valve (3-Way)

6 Concerning air-intake side distance “A” (Fig. 5a)The minimum for distance “A” is 6" if there are noobstructions on the air-discharge side (wal

Pagina 30 - Set in

7Fig. 5eFig. 5fFig. 5g2-2-1. Installing the Unit in an Area with High Winds and in a Snowy Area 425*(:0549=0://0./=04+9(=04+6855-+;*:9/5

Pagina 31 - 8. Address Switch

811-13/16" 13-3/8"25-3/16"22-7/8"(6-21/32")6-5/16"21-25/32" (12-9/16")2-11/16"35-13/16"37-1/32"

Pagina 32 - DC1111-0

9Required space around the outdoor unit-:/,=04+6855-+;*:09;9,+:/,96(*,9/5=4),25=3;9:),9,*;8,+(85;4+:/,5;:+558;40:-:/,;40:09;9

Comentarios a estos manuales

Sin comentarios